Since January 1, 1986, HECO has used adjusted intake water temperatures as the reference against which temperature elevations of the thermal effluent are measured. Intake temperatures are adjusted downward by 0.42 C' to determine the reference temperature. Based on over 10 years of temperature records collected at an ambient temperature control station, it was determined that intake temperatures exceeded nearshore ambient bottom temperatures by this amount. Daily records were kept of maximum, minimum, mean effluent, and mean influent temperatures. Intake and discharge temperatures were recorded continuously using a Foxboro ERB strip chart recorder and Dynatherm* resistance bulbs. Note to users: The complete 1996 Kahe Generating Station annual report is available under NODC Accession # 9900012, 'Kahe Generating Station NPDES Annual Report for 1996.doc'
Resource Description: NODC Accession # 9900021